1x1 spacer
header 1x1 spacerView Cartangle breakMy Account / Order Statusangle breakHelp1x1 spacer
1x1 spacer 1x1 spacer
1x1 spacer
1x1 spacer
1x1 spacer 1x1 spacer
1x1 spacer

Visit our Facebook page!

Click here to visit our blog!


hhollenbeck@workfitomaha.com



We accept Visa, Mastercard, and American Express

Certified Secure By Volusion, Inc.
Official PayPal Seal

Online Payments

Join our mailing list!

1x1 spacer
(Your shopping cart is empty)
You are here: Home > Respiratory Protection > Filters And Cartridges
Warning!

An appropriate cartridge change-out schedule must be developed by a qualified Click here to take a short quiz on Respiratory Protectionprofessional, unless the cartridge/canister utilizes an end-of-service-life indicator. The change-out schedule must take into account all factors that may influence respiratory protection including specific work practices and other conditions unique to the workers' environment. If using against substances having poor warning properties, there is no secondary means of knowing when to replace the cartridges/canister. In such cases, take appropriate additional precautions to prevent over exposure, which may include a more conservative change-out schedule or using an air-supplied respirator or SCBA. Failure to follow this warning can result in serious personal injury or death. As a reference, below is a partial list of substances having poor warning qualities:

Acrolein Hydrogen Cyanide Nitric Acid Phosphorus Trichloride
Aniline Hydrogen Selenide Nitro Compounds: Stibine
Arsine Methanol ēNitrogen Oxides Sulfur Chloride
Bromine Methyl Bromide ēNitroglycerin Urethane or other
Carbon Monoxide Methyl Chloride ēNitromethane Diisocynate-containing paints
Diisocynates Methylene Chloride Phosgene Vinyl Chloride
Dimethyl Sulfate Nickel Carbonyl Phosphine  

Definitions:

N-95 Particulate Filter (95% filter efficiency level) effective against particulate aerosols free of oil; time use restrictions may apply.

R95-Particulate Filter (95% filter efficiency level) effective against all particulate aerosols; time use restrictions may apply.

P95-Particulate Filter (95% filter efficiency level) effective against all particulate aerosols.

Notes:

  1. Do not use in atmospheres containing less than 19.5% oxygen, in atmospheres containing gasses or vapors or in atmospheres immediately dangerous to life and health.
  2. Do not use in atmospheres containing less than 19.5% oxygen, or in atmospheres immediately dangerous to life and health.
  3. Do not wear for protection against organic vapors with poor warning properties or those which generate high heats of reaction with the sorbent materials in the cartridge.
  4. 99.97% effective against 0.3 micron DOP.

Sort By:
Page of 1
3M™ Acid Gas Cartridges (2/Pack) 3M™ Air-Mate™ HE Assembly
3Mô Cartridges for facepiece respirators to protect against acid gasses.  Use in a variety of applications including chemical manufacturing, glass etching, pulp and paper, and laboratories. When properly fitted, helps provide respiratory protection from chlorine, hydrogen chloride, sulfur dioxide, or chlorine dioxide, or hydrogen sulfide (escape only) at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Not for use in environments that are immediately dangerous to life or health (IDLH). This assembly consists of the Air-Mateô HE unit, NiCd Battery Pack, HE Filter, waist belt and airflow indicator. The lightweight and comfortable assembly is designed to be worn for long periods of time on the waist of the user as part of the 3mô Air-Mateô Belt-Mounted PAPR System.
3M™ Ammonia / Methylamine Cartridges (2/Pack) 3M™ Breathe Easy™ Type P3 Cartridges (3/Pack)
3Mô Cartridges for facepiece respirators to protect against both ammonia and methylamine.  Use in a variety of applications including agriculture, chemical manufacturing, laboratories and the food industry. When properly fitted, helps provide respiratory protection from ammonia and methylamine at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Not for use in environments that are immediately dangerous to life or health (IDLH). Used with 3Mô Breathe Easyô Systems for protection against formaldehyde, chlorine, hydrogen chloride and sulfur dioxide.
3M™ Formaldehyde / Organic Vapor Cartridges (2/Pack) 3M™ Mercury Vapor / Chlorine Gas Cartridges (2/Pack)
3Mô Cartridges for facepiece respirators to protect against both formaldehyde and organic vapor.  Use in a variety of applications, including laboratories, wood processing, carpet manufacturing, and primary metals manufacturing. When properly fitted, helps provide respiratory protection from formaldehyde and certain organic vapors at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Not for use in environments that are immediately dangerous to life or health (IDLH). OSHA requires that gas-proof goggles be worn with half facepiece respirators when used against formaldehyde. 3Mô Cartridges for facepiece respirators to protect against mercury vapor and chlorine gas.  When properly fitted, helps provide respiratory protection from mercury vapor or chlorine at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Not for use in environments that are immediately dangerous to life or health (IDLH). Note: The mercury vapor end of service life indicator must be readily visible without manipulation when wearing the respirator. If not readily visible, do not use.
3M™ Multi Gas Cartridges (2/Pack) 3M™ Organic Vapor / Acid Gas Cartridges (2/Pack)
3Mô Cartridges for facepiece respirators to protect against multiple gasses.  Use in a variety of applications, including petrochemical and chemical processing, utilities, pharmaceuticals, mining and primary metals. When properly fitted, helps provide respiratory protection from certain organic vapors, chlorine, hydrogen chloride, sulfur dioxide, chlorine dioxide, hydrogen sulfide (escape only), ammonia, methylamine, formaldehyde or hydrogen fluoride at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Not for use in environments that are immediately dangerous to life or health (IDLH). OSHA requires that gas-proof goggles be worn with half facepiece respirators when used against formaldehyde. NIOSH approved against certain organic vapors. Use with 3Mô Half and Full Facepieces 6000 Series and 3Mô Half and Full Facepieces 7000 Series with bayonet style cartridge holders. Use in a variety of applications, including pharmaceutical, petrochemical, utilities, aluminum reduction, chemical manufacturing, laboratories, pul and paper, electroplating, etching, acid cleaning, acid and fertilizer manufacture.
3M™ Organic Vapor Cartridges (2/Pack) 3M™ P100 2091 Filters (2/Pack)
NIOSH approved against certain organic vapors. Use with 3Mô Half and Full Facepieces 6000 Series and 3Mô Half and Full Facepieces 7000 Series with bayonet style cartridge holders. NIOSH approved for environments containing certain oil and non-oil based particles.  When properly fitted, use in a variety of applications including welding, brazing, torch cutting, metal pouring, soldering, and exposure to lead, asbestos, cadmium, arsenic, and MDA for concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use in environments that are immediately dangerous to life or health (IDLH).
3M™ P100 Acid Gas Cartridge/Filters (2/Pack) 3M™ P100 Acid Gas Relief Filters (2/Pack)
3Mô Cartridge and filter for facepiece respirators to protect against acid gasses.  Use in a variety of applications including chemical manufacturing, glass etching, pulp and paper, and laboratories. When properly fitted, helps provide respiratory protection from chlorine, hydrogen chloride, sulfur dioxide, or chlorine dioxide, or hydrogen sulfide (escape only) and particulates at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use in environments that are immediately dangerous to life or health (IDLH). Use with 3Mô Respirators 5000 Series or 3Mô Cartridge 6000 Series with 3Mô Adapter 502, 3Mô Facepieces 6000 Series or 3Mô Facepieces 7000 Series with bayonet filter holders. When properly fitted, use in a variety of applications including welding, brazing, torch cutting, metal pouring, soldering, and exposure to lead, asbestos, cadmium, arsenic, and MDA for concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Also offers nuisance level relief from acid gases that are below the PEL. *Nuisance level refers to concentrations not exceeding OSHA PEL or other applicable government occupational exposure limits, whichever is lower. Do not use for respiratory protection against acid gases or in environments that are immediately dangerous to life or health (IDLH).
3M™ P100 Ammonia / Methylamine Cartridge/Filters (2/Pack) 3M™ P100 Formaldehyde / Organic Vapor Cartridge/Filters (2/Pack)
3Mô Cartridge and filter for facepiece respirators to protect against both ammonia and methylamine.  Use in a variety of applications including agriculture, chemical manufacturing, laboratories and the food industry. When properly fitted, helps provide respiratory protection from ammonia, methylamine and certain particulates at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use for sandblasting or in environments that are immediately dangerous to life or health (IDLH). 3Mô Cartridge and filter for facepiece respirators to protect against both formaldehyde and organic vapors.  Use in a variety of applications, including laboratories, wood processing, carpet manufacturing, and primary metals manufacturing. When properly fitted, helps provide respiratory protection from formaldehyde, certain organic vapors and particulates at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use in environments that are immediately dangerous to life or health (IDLH). OSHA requires that gas-proof goggles be worn with half facepiece respirators when used against formaldehyde.
3M™ P100 Multi Gas Cartridge/Filters (2/Pack) 3M™ P100 Organic Vapor / Acid Gas Cartridge/Filter (2/Pack)
3Mô Cartridge and filter for facepiece respirators to protect against multiple gasses.  Use in a variety of applications, including petrochemical and chemical processing, utilities, pharmaceuticals, mining and primary metals. When properly fitted, helps provide respiratory protection from certain organic vapors and particulates, chlorine, hydrogen chloride, sulfur dioxide, chlorine dioxide, hydrogen sulfide (escape only), ammonia, methylamine, formaldehyde or hydrogen fluoride at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use in environments that are immediately dangerous to life or health (IDLH). OSHA requires that gas-proof goggles be worn with half facepiece respirators when used against formaldehyde. 3Mô Cartridge and filter for facepiece respirators to protect against both organic vapors and acid gasses.  While NIOSH does not have a test procedure to certify air purifying filters against radioiodine or methyl bromide, this combination cartridge is recommended by 3M for use against radioiodine or methyl bromide at ambient concentrations up to 5 ppm and for not more than one shift. For more information, see Technical Data Bulletin #146 "Use Recommendations for 3M 60928 Cartridge/Filter." Do not use in environments that are immediately dangerous to life or health (IDLH).
3M™ P100 Organic Vapor Cartridge/Filters (2/Pack) 3M™ P100 Organic Vapor Relief Filters (2/Pack)
3Mô Cartridge and filter for facepiece respirators to protect against organic vapors.  Use in a variety of applications including petrochemical, construction, transportation and chemical manufacturing. When properly fitted, helps provide respiratory protection from certain organic vapors and particulates at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use for sandblasting or in environments that are immediately dangerous to life or health (IDLH). Use with 3Mô Respirators 5000 Series or 3Mô Cartridge 6000 Series with 3Mô Adapter 502, 3Mô Facepieces 6000 Series or 3Mô Facepieces 7000 Series with bayonet filter holders. When properly fitted, use in a variety of applications including welding, brazing, torch cutting, metal pouring, soldering, and exposure to lead, asbestos, cadmium, arsenic, and MDA for concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Also offers nuisance level relief from organic vapors that are below the PEL. *Nuisance level refers to concentrations not exceeding OSHA PEL or other applicable government occupational exposure limits, whichever is lower. Do not use for respiratory protection against acid gases or in environments that are immediately dangerous to life or health (IDLH).
3M™ P95 5P71 Pre-Filters (10/Box) 3M™ P95 Filters (2/Pack)
3Mô P95 particulate filters for use with 501 Filter Retainer.  When properly fitted, use with appropriate cartridges for various applications including spray painting, lacquering, petrochemical and chemical manufacturing, pesticide spraying and agriculture for concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. 3Mô P95 filters for use with 3Mô facemask respirators.  When properly fitted, use in a variety of applications such as grinding, sanding and welding for concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use in environments that are immediately dangerous to life or health (IDLH).
3M™ P95 Hydrogen Flouride Filters (2/Pack) 3M™ P95 Organic Vapor / Acid Gas Filters (2/Pack)
NIOSH approved for hydrogen fluoride and certain oil and non-oil based particles. 3M recommended for relief against nuisance levels of acid gases.
 When properly fitted, use in a variety of applications such as grinding, sanding and welding for concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use in environments that are immediately dangerous to life or health (IDLH).
NIOSH approved for environments containing certain oil and non-oil based particles. 3M recommended for relief against nuisance levels of organic vapor/acid gases and for ozone protection up to 10X OSHA PEL. Not NIOSH certified for use against ozone.  Use with 3Mô Respirators 5000 Series or 3Mô Cartridge 6000 Series with 3Mô Adapter 502, 3Mô Facepieces 6000 Series or 3Mô Facepieces 7000 Series with bayonet filter holders. When properly fitted, use for a variety of applications including dust, welding, metal pouring and certain finishing operations for concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Also offers nuisance level relief from organic vapors and acid gases that are below the PEL. *Nuisance level refers to concentrations not exceeding OSHA PEL or other applicable government occupational exposure limits, whichever is lower. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use in for respiratory protection against acid gases or environments that are immediately dangerous to life or health (IDLH).
3M™ PAPR GVP-402 Filters (6/Box) 3M™ PAPR GVP-404 Filters (6/Box)
This cartridge is used with the 3Mô Belt-Mounted Powered Air Purifying Respirator (PAPR) System against acid gas. It attaches to the motor blower and filters the air supplied to the headgear. This cartridge is used with the 3Mô Belt-Mounted Powered Air Purifying Respirator (PAPR) System against organic ammonia. It attaches to the motor blower and filters the air supplied to the headgear.
3M™ PAPR GVP-405 Filters (6/Box) 3M™ PAPR GVP-440 Filters (6/Box)
This cartridge is used with the 3Mô Belt-Mounted Powered Air Purifying Respirator (PAPR) System against organic formaldehyde. It attaches to the motor blower and filters the air supplied to the headgear. This HEPA Filter is used with the 3Mô Belt-Mounted Powered Air Purifying Respirator (PAPR) System. It attaches to the motor blower and filters the air supplied to the headgear.
3M™ PAPR GVP-441 Filter 3M™ PAPR GVP-442 Filters (6/Box)
3Mô PAPR GVP-441 Filter
Our Price: $101.95
This High Efficiency cartridge is used with the 3Mô Belt-Mounted Powered Air Purifying Respirator (PAPR) System against organic vapors. It attaches to the motor blower and filters the air supplied to the headgear. This High Efficiency cartridge is used with the 3Mô Belt-Mounted Powered Air Purifying Respirator (PAPR) System against acid gas. It attaches to the motor blower and filters the air supplied to the headgear.
3M™ PAPR GVP-443 Filters (6/Box) 3M™ PAPR GVP-444 Filters (6/Box)
This HEPA cartridge is used with the 3Mô Belt-Mounted Powered Air Purifying Respirator (PAPR) System against organic vapors and acid gas. It attaches to the motor blower and filters the air supplied to the headgear. This High Efficiency cartridge is used with the 3Mô Belt-Mounted Powered Air Purifying Respirator (PAPR) System against ammonia. It attaches to the motor blower and filters the air supplied to the headgear.
3M™ PAPR GVP-445 Filters (6/Box) 3M™ Particulate 5N11 Pre-Filters (10/Box)
This High Efficiency cartridge is used with the 3Mô Belt-Mounted Powered Air Purifying Respirator (PAPR) System against formaldehyde. It attaches to the motor blower and filters the air supplied to the headgear. 3Mô N95 filters for use with 501 Filter Retainer.  When properly fitted, use with appropriate cartridges for various applications including spray painting, petrochemical and chemical manufacturing, and pesticide spraying for concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use for aerosols containing oil or in environments that are immediately dangerous to life or health (IDLH).
3M™ Powerflow™ HE SP3 Filters (20/Box) 3M Prefilter Retainer Cap
This HE (High Efficiency) Sp3 Filter is used with the 3Mô Powerflowô PAPR System for protection against high efficiency particulates. Used to hold 3Mô Particulate Filters 5N11 and 5P71/07194(AAD) in place on top of 3Mô Respirators 5000 Series and 3Mô Cartridges 6000 Series.
Allegro® Clear Respirator Storage Bag MSA Organic Vapors/Chlorine/Sulfur Dioxide/Chlorine Dioxide/Hydrogen Chloride/Hydrogen Sulfide (Escape Only) GMC Chemical & Combination APR Cartridge
Reusable 10 mil storage bag to keep equipment contaminant-free. Large 14" x 16" transparent bag with zipper closure. Also features respirator cleaning instructions printed on the outside of bag. MSA GMC Cartridge is compatible with Advantageģ series and Comfoģ series air purifying respirator and is designed to offer a high level of protection from organic vapors and myriad contaminants.
   
 
Type of Filters and Efficiences
Filters are classified in two ways: the Filter Type and the Efficiency. Each group has three levels, for a total of nine possible filter classifications.

NIOSH 42CFR84:
Personal Protective Equipment Particulate Respirator Filter Definitions

Filter Series
Filter Designation
Minimum Efficiency
N (Non-Oil)
N100
99.97%
 
N99
99%
 
N95
95%
R (Oil-Resistant)
R100
99.97%
 
R99
99%
 
R95
95%
P (Oil-Proof)
P100
99.97%
 
P99
99%
 
P95
95%

Respirator Cartridge Color Coding

Cartridge ColorCartridge Use
                              Black
OV: Organic Vapors
                              
White
AG: Acid Gases
                              Yellow
OV/AG: Organic Vapors, Acid Gases
                              Green
AM/MA: Ammonia, Methylamine
                              Brown
OV/AG/AM: Organic Vapors, Acid Gases, Ammonia
                              Tan
OV/CL/CD/HC/HF/SD/F/HS (escape)/ AM/MA: Organic Vapors, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Fluoride, Sulfur Dioxide, Formaldehyde, Hydrogen Sulfide (E), Ammonia, Methylamine
                              Olive
Other Vapors And Gases Or Combinations Not Listed Above
1x1 spacer
1x1 spacer www.thecuresafety.com
4950 Grover St
Omaha, NE 68106
(402) 553-8816
footer
1x1 spacer
 About Us
1x1 spacer
 Return Policy
1x1 spacer
 Privacy Policy
1x1 spacer
 Send Us Feedback
 
1x1 spacer
Company Info | Advertising | Product Index | Category Index | Help | Terms of Use
Copyright © 2015 www.thecuresafety.com All Rights Reserved.
Built with Volusion